Additional requirements. If you have any – any requirement for additional flow options, discuss them necessarily, and if possible execution – production. Example Objective: To measure the production line in volume flow additive with a density 800-900kg/m3, 10000-50000 cP viscosity, flow 5-50kg/chas, ambient temperature of 90-120 degrees. Celsius ambient temperature +5 – +20 degrees Celsius, the measurement accuracy better than 0,5%, the line pressure 6 bar, flanged, you need a remote electronic bypass adder with indication of evidence in the case with DIN and output an analog signal, as well as with alarm at the large and small stream. Based on this task, we need a set of flow meter with pulse output and electronic adder RT12, which has all the necessary functions (alarms, analog output). 1. Recalculate the flow volume of the mass, in terms of density.
2. Accuracy of measurements for such highly viscous liquids even without the use of linearization corresponds to the requirements of the customer. There is an inverse relationship – the more highly viscous liquid, we measure, the less the impact of factors that can impair the accuracy and hence better accuracy. 3. Highly viscous liquid – just refuse to use the turbine and blade models. After the conversion rate in accordance with the methodology for measuring highly viscous liquids, we see (through counting the volume density), which required meter with an operating range: for flow series and the OM MG – 41,5-520 l / h flow series with OM and MG special treatment of teeth Gear – 22,0-250 l / h flow MR Series – – 11,0-125 liters / hour.